40MHz, 2 CHANNEL, 4 TRACE OSCILLOSCOPE   Model 3804

Features

  • TV Triggering Frame (V) & Line (H)
  • Line Trigger
  • Elegant
  • DC to 40MHz Bandwidth
  • 1mV/div Sensitivity on Both Channels
  • CH1 & CH2 Independent Channels
  • Algebraic Addition and Subtraction
  • X-Y Operation
  • 20ns/div to 0.2s/div Time Base
  • ALT MAG. Trace - Max. 4 Traces
  • Scale Illumination
  • Z Modulation
  • 8 x 10 cm Display Internal Graticule
  • Auto Focus
Technical Specifications
VERTICAL DEFLECTION (Y)
Deflection Coefficient (CH1 & CH2) 1mV/div to 5V/div. 5mV/div to 5V/div in 10 calibrated steps in 1-2-5 sequence. x5 Magnification increases the sensitivity to 1mV/div to 1V/div.
Accuracy x1 : ±3%, x5 : ±5%.
Variable 1 / 2.5 times uncalibrated continuously variable control extends the Deflection Coefficient to more than 12.5V/div.
Bandwidth x1 : DC to 40MHz (-3dB), dc coupled.
10Hz to 40MHz (-3dB), ac coupled.
x5 : DC to 7MHz (dc coupled)
10Hz to 7MHz (ac coupled).
Rise Time 8.8 ns or less.
Display Modes CH1 only, CH2 only, CH1 & CH2 alternate or chop mode, Algebraic additon CH1+CH2, Algebraic subtraction CH1 - CH2, CH2 invert & X-Y.
Input Impedance 1M ohms & 25pF approx.
Maximum Input Voltage 300 Volts (dc + peak ac).
Internal Trigger Signal CH1 or CH2.
TIME BASE
Sweep Speed 20 Calibrated steps. 0.1µs/div to 0.2s/div in 1, 2 & 5 sequence.
Sweep Magnifier x5 Magnification.
Accuracy ±3%.
Variable Uncalibrated continuously variable control between steps, extends slowest sweep speed to 0.5s/div (approx.).
ALT MAG Trace x5 magnified sweep is displayed along with normal sweep.
TRIGGER SYSTEM
Triggering Mode AUTO, NORM, TV-V, TV-H.
Source CH1 / CH2 / LINE / EXT.
Slope Positive or Negative.
Coupling ac coupling.
Trigger Sensitivity  
Internal Auto : 2 div - 20Hz to 40MHz.
Normal : 2 div - 10Hz to 40MHz.
External Auto 0.8V p-p - 20Hz to 40MHz.
Normal 0.8V p-p - 10Hz to 40MHz.
Lock 0.8V - 50Hz to 40MHz.
HORIZONTAL DEFLECTION
Deflection Coefficient Same as CH1.
Bandwidth DC - 500KHz (-3dB).
Input Impedance 1M ohms & 25pF approx.
Phase Difference <3º (DC - 50KHz).
GENERAL INFORMATION
Cathode Ray Tube 140mm Rectangular screen, Internal Graticule, 8 x 10 cm, P31 phosphor.
Accelerating potential : 12KV.
Z-Modulation ±5V p-p signal upto 2MHz modulates at normal intensity.
Calibrator Provides 0.5V ±2%, 1KHz ±2% square-wave output for probe compensation.
Power Requirement 220V AC ±10%, 50Hz ±5%, 35VA (max.).
Dimensions 140 (H) x 335 (W) x 375 (D) mm approx.
Weight 7.2 Kgs. approx.
Accessories Instruction Manual, 2 High impedance switch probe with x1 or x10 attenuation, Mains Cord.