| Technical Specifications |
| VERTICAL DEFLECTION |
| Deflection Coefficient (CH1 & CH2) |
1mV/div to 20V/div. 5mV/div to 20V/div in 12 calibrated steps
in 1-2-5 sequence. x5 magnification increases sensitivity to
1mV/div and 2mV/div (LED indication). |
| Accuracy |
±3%. |
| Bandwidth |
DC - 20MHz (-3dB), dc coupled. 10Hz - 20MHz (-3dB), ac
coupled. DC - 28MHz (-6dB). |
| Rise Time |
17.5nsec or less. |
| Display Modes |
CH1, CH2, CH1 & CH2 Alternate or Chop mode & X-Y,
CH1-Y, CH2-X, Algebraic ADD and SUBTRACT with CH2-INVT. |
| Input Impedance |
1M ohms & 25pF (approx). |
| Maximum Input Voltage |
500 Volts (dc + peak ac). |
| Internal Trigger Signal |
CH1 or CH2. |
| TIME BASE |
| Sweep Speed |
18 calibrated steps. 0.5µS/div to 0.2S/div in 1, 2 & 5
sequence. |
| Sweep Magnifier |
x5 Magnification extends the sweep speed to 100nS/div. x5
Magnification indication with LED. |
| Accuracy |
±3%. |
| Variable |
Uncalibrated continuously variable control between steps,
extends fastest sweep speed to 40nS/div (approx). (Uncal LED
indication). |
| TRIGGER SYSTEM |
| Triggering Mode |
Automatic or Normal with Level Control. |
| Source |
CH1 / CH2 / LINE / EXT. |
| Slope |
Positive or Negative. |
| Coupling |
ac / dc / HF reject or TV Frame / TV Line. |
| Trigger Sensitivity |
|
| Internal |
AUTO 0.5 div 30Hz - 20MHz NORM 0.5 div 3Hz -
20MHz. |
| External |
AUTO 0.8V p-p 30Hz - 20MHz NORM 0.8V p-p 3Hz -
20MHz. (Typical 40MHz). |
| HORIZONTAL DEFLECTION |
| Deflection Coefficient |
Same as CH2. |
| Bandwidth |
DC - 2.5MHz (-3dB). Phase shift <3 deg. at 60KHz.
|
| Input Impedance |
1M ohms and 25pF (approx.). |
| COMPONENT TESTER |
Component Tester allows V-I characteristics of a Device -
Under Test (D.U.T.). |
| Test Voltage |
8.6V r.m.s. |
| Test Current |
28mA max. |
| Test Frequency |
50Hz or 60Hz (Mains). |
| GENERAL INFORMATION |
| Cathode Ray Tube |
140mm Rectangular screen, Internal Graticule, 8 x 10 cm, P43
phosphor. Accelerating potential : 2KV. |
| Trace Rotation |
Front Panel control, allows ±5º of trace
adjustment. |
| Z - Modulation |
TTL level. |
| Calibrator |
Provides 0.2V ±1%, 1KHz (approx) squarewave output for probe
compensation. |
| Power Requirement |
230V AC ±10%, 47-65Hz, 40VA or 115V AC ±10% (on
request). |
| Dimensions |
165 (H) x 320 (W) x 420 (D) mm approx. |
| Weight |
8.0 Kgs. approx. |
| Accessories |
Manual with Circuit Diagrams - 1 No. BNC-Crocodile Cable -
1 No. Component Tester Lead - 1 No. Optional : High impedance
switch probe with x1 or x10 Attenuation (Model 306), Trolley (Model
304). |
| Environmental Specifications |
Normal : 10ºC to 40ºC RH 85%. Operational : 0ºC to 50ºC RH
85%. |